bidones-tecnocoat

TECNOCOAT H-2049 LV

Low-viscosity polyurea membrane for wateproofing and coating

TECNOCOAT H-2049 LV is a two-component, low-viscosity, sprayable, aromatic coating suitable for waterproofing, protection, and sealing. It's made up of two high reactive liquid components, isocyanates and amines, which are mixed using our specific spray equipment (TC2049) or similar, to form a solid, continuous, watertight and waterproof, seamless, high-density polyurea membrane, with mechanical qualities especially for protecting the spray polyurethane foams systems TECNOFOAM (SPF).

It has CE marking on the basis of a statement made DoP Declaration of Performance (DoP) conforms to the UE 305/2011 regulation.



ce



MSDS, CERTIFICATES, APPROVALS...(link)
DoP EN1504(PDF)

Uses

For waterproofing and protection of:

  • Flat or sloped asbestos roofs (used with TECNOFOAM, spray polyurethane foam system)
  • As a protection for SPF (TECNOFOAM spray polyurethane foam system)
  • Furniture and thematizations
  • Vehicle and boat coatings(bed liners)
  • ROOFING: Sloped and flat roofs (walkable), balconies, and overhangs.
  • IRMA roofing system
  • Concrete decks, retaining walls, and foundations 

NOTE: call our technical department about the application to other supports or situations.

recommended minimum thickness ±1,5 mm
tack-free time 15~17 secs
tensile strength ±13 MPa
elongation >250 %
shore A hardness >85
application method medium pressure spray equipment
VOC(volatile organic compounds) 0

GENERAL FEATURES

  • TECNOCOAT H-2049 LV is an elastic and hard-wearing product that once applied, offers waterproofing, great stability, and durability.
  • The application and training are done by our spray equipment TC2049 (spray-equipment.tecnopolgroup.com) or similar
  • thanks to its versatility and its drying time of between 15 and 17 seconds TECNOCOAT H-2049 adapts to any surface, making it the ideal product for application on uneven surfaces and in areas of any shape, whether curved or squared.
  • it saves in seals and any other kind of joins, as the finish is uniform and makes up a single layer, providing a surface with optimum maintenance and cleaning properties.
  • recommended consumption is approximately 1,7 kg/sqm (at 1,5 mm dry film thickness). This data could vary depending on the type of application, weather conditions, or substrates' nature.
  • it should be applied in dry conditions avoiding the presence of humidity or coming from the surface to be coated or the substrate, whether at the time of application or subsequently (pressure from phreatic water level). In the event there is humidity in the substrate at the time of application, consult the technical specifications of our primers in the TDS.
  • the system's properties enable it to bond to any surface, such as cement, concrete, polyurethane, wood, metal, etc. Furthermore, due to its resistance, it can be walked on and it will accept a rough finish to make it non-slip (according to ENV 12633:2003)
  • his properties allow it to adhere to any surface such as concrete, ceramic tiles, metals, spray polyurethane foam (Tecnofoam), plywood, asphalt/bituminous sheets. In any case or material, the surface must be consistent, firm, clean, and dry when the products are applied. Recommended applying directly on the concrete deck. Ponding water admitted.
  • free from harmful VOC compounds, therefore, it does not hurt the ozone layer (VOC's zero). It's 100% recyclable by mechanical means friendly to the environment; no gas collection for recycling and/or destruction is required; it doesn´t emit substance to the environment once installed.
  • the system requires solar radiation protection (UV rays) to do not lose its physical and mechanical properties, given that it is an aromatic membrane. The system incorporates a protective polyurethane-colored aliphatic resin, TECNOTOP 2C, for use in the absence of other physical protection elements. You can apply too TECNOTOP S-3000, TECNOTOP 2CP or TECNOTOP 1C.

PACKAGING

Metal drums of 225 kg each component (B side: resines and A side: isocyanates).

SHELF LIFE

12 months at temperatures between 5°C to 35°C, provided it is stored in a dry place, keep away from direct sunlight, extreme heat, cold, or moisture. Once the tin has been opened, the product must be used. Once opening drum, B side must be agitated mechanically before inserting the transfer pumps and use.

APPLICATION METHOD

For the formation of the solid membrane TECNOCOAT H-2049 LV, it is necessary to mix the two initial liquid components through specialized reactor equipment. (Proper maintenance and cleaning are recommended).

  • repair the surface (fill in depressions, eliminate unevenness, eliminate any old waterproofing, etc.)
  • singular points preparation(perimeter, sinks / evacuations, expansion joints or structural)
  • clean up the surface or substrate, removing any dust, dirt, grease, or efflorescence.
  • the surface has to be enough compressive strength of adhesion of the membrane. If it were not so, we will proceed to apply our primers resins to achieve this target
  • the pull-off strength of the membrane will be minimal 1,5 MPa
  • in case of doubt of all above, apply before in a restricted area and to check

The TECNOCOAT H-2049 LV pure polyurea system can be applied to many different surfaces and the procedure will vary depending on its nature or state.

Below we set out some of the applications for the most common surfaces; for other surfaces not described, please contact our technical department.

Concrete substrate

  • any depressions or voids should be repaired using a mix (ratio of ±1:4) of our epoxy resin PRIMER EP-1020  mixed with silica sand.
  • the concrete should be completely cured (concrete curing takes 28 days) or, in any case, the maximum level of humidity allowed for the substrate should be verified, depending on the primer used.
  • any concrete laitance or release agents should be eliminated and open the pore surface achieved by grit blasting, milling, or sanding.
  • next, clean and eliminate all contaminants from the elements, such as dust or particles from the previous processes.
  • apply the primer in the conditions and with the parameters indicated in the technical specifications for these products. In general, the two-component polyurethane PRIMER PU-1050/PRIMER PUc-1050, the epoxies PRIMER EP-1010, PRIMER EP-1020, or PRIMER EPw-1070 should be used, to promote adherence to the concrete surface, reduce the pinhole appearance, and absorption of moisture in the substrate (please check the primers absorption capacity in the TDS)
  • apply the TECNOCOAT H-2049 LV polyurea membrane
  • application of the aliphatic resin TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays.

Metal substrate

  • metal surfaces should be prepared using sand-blasting, in order to improve the surface's mechanical fixation properties.
  • check the seals and overlaps and where necessary seal with MASTIC PU mastic or TECNOBAND 100, in combination.
  • for rapid and efficient cleaning of the surface using a ketone-based solvent.
  • apply prior priming using PRIMER EP-1040 or PRIMER EPw-1070, to improve surface leveling and bonding. Consult the technical specifications of these products.
  • apply the TECNOCOAT H-2049 LV polyurea membrane.
  • application of the aliphatic resin TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays. 

Ceramic substrate

  • ceramic surfaces should not have empty joints or loose elements or parts. These should be filled with MASTIC PU mastic, complemented with TECNOBAND 100 on the joints if necessary.
  • for rapid and efficient cleaning of the surface use pressurized water and check that it evaporates completely. Also, verify that all dust and other physical contaminants have been eliminated.
  • apply the required primer; in these cases, non-porous surfaces use PRIMER EP-1040, PRIMER EP-1010, or PRIMER EPw-1070.
  • apply the TECNOCOAT H-2049 LV polyurea membrane.
  • application of the aliphatic resin TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays.

Sheets:

The existing sheet surfaces (bitumen, EPDM, PVC ...) must not show surface areas raised or not in good condition. He withdrew in poor areas.

  • there shall be cleaned with water, ensuring complete evaporation.
  • next, apply the required primer; in these cases of non-porous surfaces use the water-based epoxy PRIMER EPw-1070.
  • apply the TECNOCOAT H-2049 LV polyurea membrane.
  • application of the aliphatic resin TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays. 

Notes:

  • Consult in all cases the waiting times, drying time, singular points treatment, conditions of application of all the products through the technical data sheets of each product or consult our technical department.
  • For other types of supports/substrates, for further information on the execution application procedure, for any additional questions, please, consult the technical data sheets (TDS) of these products, or our technical department.
  • These guidelines are valid although they can be modified, according to the situation of the supports, conditioning of the bearing structures of the elements to be waterproofed, external climatology or situation at the time of application

REPAIR AND OVERLAPS PROCESSES

REPAIR
In cases where the membrane repair by accidental causes, or assembly procedures not covered installations, shall be as follows:

  • cut, removal of the affected area and/or damaged surface
  • sanding this area extending about 20~30 cm. around the perimeter, for overlapping security
  • cleaning (vacuuming) of waste generated (powder, dust...); if it's possible don't use water, and if used, support humidity value; ketones applicability based solvents for reducing this type of surface cleaning
  • apply a thin layer (100-150 g/m²) of polyurethane resin PRIMER PU-1050, PRIMER EPw-1070
  • light spread SILICA SAND over the wet primer applied before
  • wait for the total drying
  • apply TECNOCOAT H-2049 LV
  • apply TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays.

OVERLAPS
In cases has been exceeded recoat time (24~48 hours), so the waiting time between jobs is prolonged, proceed as follows:

  • sanding strip longitudinal overlap of about 20~30 cm. wide
  • cleaning (vacuuming) of waste generated (powder, dust...)or existing dust; if it's possible, do not use water, and if it's used, check the support humidity value; ketones applicability based solvents for conducting this type of surface cleaning
  • apply a thin layer (100-150 g/m²) of polyurethane resin PRIMER PU-1050, PRIMER EPw-1070
  • light spread SILICA SAND over the wet primer applied before
  • wait for the total drying
  • apply TECNOCOAT H-2049 LV
  • apply TECNOTOP S-3000/2C/2CP/1C, in consumption and desired thicknesses in the case of no protection against UV rays. 

APPLICATION REQUIREMENTS (spray equipment)

For the formation, it is necessary to mix the two initial liquid components, isocyanates and amines by our spray equipment TC2049 (spray-equipment.tecnopolgroup.com) or similar (proper maintenance and cleaning it is recommended). The general parameters for this material will be the following:

  • Heater isocyanate temperature:60-65 ºC
  • Heater amines temperature:60-65ºC
  • Hose temperature:±65ºC
  • Working pressure: 2.500 - 3.000 psi
  • Recommended mixing chamber: GU-07008-1 or GU-07008-2

These temperature and pressure parameters have to be valued, ratified, or be varied by the applicator, depending on the conditions of each climate zone, weather situation, or projection equipment specifications.

HANDLING AND SAFETY

These safety recommendations for handling, are necessary for the implementation process as well as in the pre and post, on exposure to the loading machinery. Always read the MSDS before use and handling the product.

  • Respiratory Protection: When handling or spraying use an air-purifying respirator.
  • Skin protection: Use rubber gloves, remove immediately after contamination. Wear clean body-covering. Wash thoroughly with soap and water after work and before eating, drinking, or smoking.
  • Eye / Face: Wear safety goggles to prevent splashing and exposure to particles in the air.
  • Waste: Waste generation should be avoided or minimized. Incinerate under controlled conditions in accordance with local laws and national regulations.
  • Vapor and atomized liquids are harmful
  • Use only in ventilated areas, wear approved respirators when necessary
  • Keep out of reach of children
  • Do not use near high heat or open flame

Anyway, consult the material and safety data sheet (MSDS) of the product. To obtain an MSDS, please call +34935682111 or send an email to dpont@tecnopol.es

COMPLEMENTARY PRODUCTS

The TECNOCOAT H-2049 LV system may be complemented with the following products as a means of protection or to improve its physical-mechanical properties depending on its exposure, the desired finish, or the type of substrate.

  • PRIMER EP-1010: 100% solids, two-component, fillerized epoxy resin, to fill in depressions in concrete surfaces, one coat application so,  rapidly providing a firm and fast drying even base.
  • PRIMER EP-1020: 100% solids, two-component,  epoxy resin, improving the adhesion, in one coat application so,  rapidly providing a firm and fast drying even base.
  • PRIMER PU-1050/PUc-1050:these several resins are applied on the substrate beforehand to improve bonding and level the surface and regulate the humidity in the substrate (see permitted levels in their technical specifications).
  • PRIMER EP-1040: epoxy resin for its previous application on metallic or ceramic supports, improving adhesion, absorbing resident moisture in the support, and regularizing the planimetry of the support.
  • PRIMER EPw-1070: epoxy water-based resin for the application on concrete, asphalt sheets, metal, or ceramic, improving adhesion, absorbing resident moisture in the support.
    PRIMER WET: epoxy resin for the application on concrete or ceramic substrates, improving adhesion, absorbing resident moisture in the substrate.
  • TECNOCOAT CP-2049: pure cold polyurea coating for manual application, self-leveling for waterproofing. 
  • TECNOCOAT CP-2049 PLUS: pure cold polyurea coating for manual application, self-leveling for waterproofing. It is certified by a European Technical Approval  (ETA 20/0253) under EAD 030350-0402 for roofing.
  • TECNOTOP 2C: dual-component, glossy, and colored aliphatic polyurethane resin, used to protect walkable and vehicular roofs and floors or ground against UV rays when there is no other protection.
  • TECNOTOP 2CP: dual-component, satin and colored aliphatic polyurethane resin used to protect against UV rays and chlorinated/salted water for swimming pools, lakes, and aquariums waterproofing.
  • TECNOTOP 1C: single component, glossy, and colored aliphatic, used to protect non-walkable roofs or only for maintenance, against UV rays when there is no other protection
  • TECNOTOP S-3000: polyaspartic resin two-component, aliphatic, colored, coating for protection against UV rays, quick dry time, and excellent chemical and mechanical characteristics.
  • TECNOPLASTIC: this plastic powder, once mixed with TECNOTOP 2C/2CP/S-3000/1C, forms a rough surface, conforming even to norm ENV 12633:2003 (floors slipperiness), to achieve Class 3 (>45 slip resistance), depending on dosage (consult our technical department).
  • TECNOBAND 100: the cold bond deformable band made up of an upper layer of non-woven textile and a lower layer of viscoelastic self-adhesive coating, which together allow it to adapt to the shape of the substrate. This band is ideal when dealing with structural joints and overlapping metal materials.
  • TECNOBAND 200 FLEX: elastic, rubber band for structural joints with high movement
  • TECNOMESH 200 BASE: non-woven woven for previous placement on excessively irregular substrates or in areas of earth or natural substrate.
  • MASTIC PU: polyurethane mastic for filling joints (use together with TECNOBAND 100 when necessary).

TECHNICAL DATA  OF COMPONENTS

PROPERTIES

COMPONENT A

COMPONENT B*

Density     ISO 1675

1,10±0,05 g/cm³

1,09 ±0,05 g/cm³

Viscosity (at 12 rpm) ISO 2555

300±50 cps

8000±50 cps

Mix ratio – in weight

100

102

Mix ratio – in volume

100

100

* Data for component B pigmented in gray. For other colorations or neutral, consult the official COA issued by Tecnopol (Certificate of Analysis for each batch delivered). Results were performed in the laboratory at 23ºC and 50% RH, under controllable conditions.

MEMBRANE PROPERTIES

PROPERTIES

RESULTS

Density     ISO 1675

±1,15 g/cm³

Tack-free time  ±15~17 sec
Cured time ±12 hours

Elongation at break         ISO 527-3

>250%

Tensile Strength     ISO 527-3

>13 MPa

Hardness Shore A/D     DIN 53.505

>85 / >45

Environmental and support  application temperature range 5ºC ~ 40ºC
Max. relative humidity 80%
Walkable ±3 hours

Construction element slope

 zero slope, ponding water admitted

Fire reaction

NPD

VOC(volatile organic compounds)

Solid Content   ISO 1768 100%
Adherence to concrete > 2 MPa

Results were performed in the laboratory at 23ºC and 50% RH, under controllable conditions. These values may vary depending on the application, climatology, or substrate conditions.