bidones

PRIMER EP-1040

Two-component, 100 % solids, epoxy resin as a primer

It’s a two-component primer, epoxy resin-based 100% solids, to use as a primer, to increase adherence of TECNOCOAT and DESMOPOL waterproofing liquid systems, in applications on metal surfaces. (smooth surfaces)

Download PDF data sheet . PRIMER EP-1040TDS. Technical Data sheet Download all documents . PRIMER EP-1040Downloads

Uses

Epoxy resin to use :

  • to improve the adherence on metal surfaces and ceramic tiles(smooth finishing)
  • to stop the oxidation or corrosion processes
  • to seal on concrete surfaces

NOTE: call our technical department about the application to other supports or situations

density at 23ºC 1,05 g/cm³
viscosity at 23ºC 850 cps
pot life at 23ºC ± 40 minutes
drying  time at 23ºC 4~6 hours
approx. coat consumption ±150 g/m2
mix ratio 1,6:1

GENERAL FEATURES

  • 100% solids, epoxy resin
  • Excellent adhesion on metal surfaces
  • stops corrosion and oxidation processes
  • Odorless, and solvent-free.
  • Do not add water or any solvent.
  • Consumption on metal surfaces 150-200 g/m², applied on thin coats
  • It can be applied on surfaces with a maximum surface humidity of 4%.
  • Do not apply at temp. below. 10 ºC or more than 30 ºC, or with relative moisture more than 80%. Do not use hot air guns that burn fossil fuels. These conditions facilitate the appearance of white spots. Use electric heaters.
  • Translucent once applied.
  • The PRIMER EP-1040 should be applied in dry conditions avoiding the presence of humidity or water coming from the surface to be coated or the substrate, whether at the time of application or subsequently (pressure from phreatic water level).

PRESENTATION

Kit metal tins: 8 kg.+5kg.

SHELF LIFE

12 months for each product at temperatures between 5° C and 35° C, provided it is stored in a dry place. Once the tin has been opened, the product must be used immediately.

APPLICATION METHOD

  • The surface must be clean, free of loose particles, grease, oil, or damaged paintings.
  • Remove oxidation or corrosion areas
  • Both temperature, environmental and support, should be at least 3 higher than the dew point at the time of the application, so the risk of condensation is reduced
  • PRIMER EP-1040 comes in pre-weighed containers suitable for subsequent mixing proportions, partial mixtures is not recommended.
  • Pour the contents of Comp. II on Comp. I, and mix with a drill fitted with a stirrer at low speed until achieving a homogeneous product. Special emphasis on shaking the walls and bottom of the container.
  • Do not add water or any solvents.
  • Apply PRIMER EP-1040 with the help of a short-haired roller on the support. applying a second layer will be necessary for very absorbent substrates.

Notes:

  • Consult in all cases the waiting times, drying time, singular points treatment, conditions of application of all the products through the technical data sheets of each product, the technical handbook of application of TECNOCOAT, or consult our technical department.
  • For other types of supports/substrates, for further information on the execution application procedure, for any additional questions, please, consult the technical data sheets (TDS) of these products, or our technical department.
  • These guidelines are valid although they can be modified, according to the situation of the supports, conditioning of the bearing structures of the elements to be waterproofed, external climatology or situation at the time of application

HANDLING

These safety recommendations for handling, are necessary for the implementation process as well as in the pre and post, on exposure to the loading machinery.

  • Respiratory Protection: When handling or spraying use an air-purifying respirator.
  • Skin protection: Use rubber gloves, remove immediately after contamination. Wear clean body-covering. Wash thoroughly with soap and water after work and before eating, drinking, or smoking.
  • Eye / Face: Wear safety goggles to prevent splashing and exposure to particles in the air.
  • Waste: Waste generation should be avoided or minimized. Incinerate under controlled conditions in accordance with local laws and national regulations.

Anyway, consult the material and safety data sheet of the product (MSDS) or contact our technical department.


PROPERTIES

PROPERTIES

VALUE

Density at 23 ºC    ISO 1675

1.05 g/cm³

Viscosity at 23ºC    ISO 2555

850 cps

Density comp. A at 23 ºC    ISO 1675 1.25 g/cm³
Density comp. B at 23 ºC    ISO 1675 1.10 g/cm³
Viscosity comp. A at 23ºC    ISO 2555 1.100 - 1.300 cps
Viscosity comp. Bat 23ºC    ISO 2555 250 - 500 cps
Solids content   ISO 1768 100%
VOC(volatile organic compounds) 0

Shore D at 23ªC    DIN 53.505

>75

Adhesion to the concrete

>2 MPa

Pot life at 23 ºC

±40 minutes

Tack-free time 23 ºC

±60 minutes

Drying time at 23 ºC

±4~6 hours

Recoat range time at 23 ºC

4~48 hours

Service range temperature 

-20~80 ºC

Environmental application range of temperature

5~35 ºC

Max. moisture on the support

±4%

Max. environmental moisture

±80%

Dilution

NEVER

These values in this table are approximate and can vary depending on the situation of the carrier or application methodology employed